The 3-phase bidirectional power meter EMU Professional II 3/100 M-Bus for DIN rail mounting features a built-in wired M-Bus interface and is suitable for energy management as per ISO 50001 and energy cost billing.Logbook for events and configuration changes related to MID / PTB regulations and Built-in load profile memory with a memory depth of over 3 years at a 15-minute interval.
Features
Bidirectional three-phase power meter with M-Bus interface
wired M-Bus interface
Logbook for events and configuration changes
Logging of different measurement values and export via M-Bus
Memory depth of over 3 years at a 15-minute interval
Buffered clock with synchronisation via M-Bus
3x230/400V
Direct connection up to 100 A
MID B+D, for billing purposes
PTB-A 50.7 approval
Accuracy class B (1%)
M-Bus interface
The built-in M-Bus interface is protected against dirt and manipulation and is designed according to EN13757-2, -3 (previously EN1434-3). The power meter EMU Professional II 3/100 M-Bus communicates via M-Bus at 300, 600, 1,200, 2,400, 4,800 and 9,600 baud. The M-Bus load of the EMU Professional II 3/100 M-Bus LP is only 1.5 mA, which corresponds to a standard load.M-Bus connection: The EMU Professional 3/100 M-Bus LP 2x2 M-Bus connection terminals for easy M-Bus looping.
Power meter readings
Active energy consumption (kWh) and supply (kWh)
Reactive energy consumption (kvarh) and supply (kvarh)
Active power (kw)
Reactive power (kvar)
Apparent power (kVA)
Current (A)
Frequency (Hz)
Number of voltage failures
LCD-Display
Reading and setting parameters is user-friendly by a 38x28 mm graphic LCD display with LED backlight. This provides excellent visibility of numbers and letters.Display language e.g. english or german can be selected by the keys.
Power meter configuration
Touch-sensitive control buttons are used for configuration. A sealable service button must be pressed for each configuration change.The control keys are used to configure the M-Bus primary and secondary address, and the baud rate.
M-Bus baud rate: Via keys or free EMU MB-Connect software
M-Bus primary address: Via keys or free EMU MB-Connect software
M-Bus secondary address: Via keys or free EMU MB-Connect software
S0 pulse output
The 3-phase power meter EMU Professional II 3/100 M-Bus features a configurable S0 pulse output for active or reactive energy
Pulse rate per kWh / kvarH: 1,10,100, 1000 or 10000
Pulse length in milliseconds: 2ms, 10ms, 30ms, 40ms, 120 ms
Power meter configuration ex factory
M-Bus primary address: 000
M-Bus secondary address: serial number, e.g. 24501234
M-Bus baud rate: 2400
S0 pulse output: 1'000 Impulse/ 40 ms
Manufacturer
The 3-phase M-Bus power meter meter is produced in Switzerland by EMU Electronic Ltd.More information: https://www.emuag.ch
Demandez un login B2B pour voir les prix et les rabais.
The 3-phase bidirectional power meter EMU Professional II 3/5 M-Bus for DIN rail mounting features a built-in wired M-Bus interface and is suitable for energy management as per ISO 50001 and energy cost billing.The EMU Professional II 3/5 M-Bus LP features a logbook for events and configuration changes (eg. CT ratio) related to MID / PTB regulations. Built-in load profile memory with a memory depth of over 3 years at a 15-minute interval. Historical data can be exported via M-Bus using e.g. the EMU M-Bus Center.
Features
Bidirectional three-phase power meter with M-Bus interface
wired M-Bus interface
Logbook for events and configuration changes
Logging of different measurement values and export via M-Bus
Memory depth of over 3 years at a 15-minute interval
Buffered clock with synchronisation via M-Bus
3x230/400V
Indirect using /5A and /1A current transformers
Current transformer ratio configurable several times using the service key
MID B+D, for billing purposes
Accuracy class B (1%)
M-Bus interface
The built-in M-Bus interface is protected against dirt and manipulation and is designed according to EN13757-2, -3 (previously EN1434-3). The power meter EMU Professional II 3/5 M-Bus LP communicates via M-Bus at 300, 600, 1,200, 2,400, 4,800 and 9,600 baud. The M-Bus load of the EMU Professional II 3/5 M-Bus LP is only 1.5 mA, which corresponds to a standard load.M-Bus connection: The EMU Professional 3/5 M-Bus LP 2x2 M-Bus connection terminals for easy M-Bus looping.
Power meter readings
Active energy consumption (kWh) and supply (kWh)
Reactive energy consumption (kWh) and supply (kWh)
Active power (kw)
Reactive power (kvar)
Apparent power (kVA)
Current (A)
Frequency (Hz)
Number of voltage failures
Current transformer ratio
LCD-Display
Reading and setting parameters is user-friendly by a 38x28 mm graphic LCD display with LED backlight. This provides excellent visibility of numbers and letters.Display language e.g. english or german can be selected by the keys.
Power meter configuration
Touch-sensitive control buttons are used for configuration. A sealable service button must be pressed for each configuration change.The current transformer ratio (1 or 5 A transformer, up for up to 20000/5 or 4000/1 A) can be configurable several times.The control keys are used to configure the M-Bus primary and secondary address, and the baud rate.
M-Bus baud rate: Via keys or free EMU MB-Connect software
M-Bus primary address: Via keys or free EMU MB-Connect software
M-Bus secondary address: Via keys or free EMU MB-Connect software
S0 pulse output
The 3-phase indirect power meter EMU Professional II 3/5 M-Bus LP features a configurable S0 pulse output for active or reactive energy
Pulse rate per kWh / kvarH: 1,10,100, 1000 or 10000
Pulse length in milliseconds: 2ms, 10ms, 30ms, 40ms, 120 ms
Power meter configuration ex factory
M-Bus secondary address: serial number, e.g. 23521234
M-Bus primary address: 000
M-Bus baud rate: 2400
S0 pulse output: 10 Impulse/ 20 ms
Power meter manufacturer
The 3-phase indirect M-Bus power meter meter is produced in Switzerland by EMU Electronic Ltd.More information: https://www.emuag.ch
Demandez un login B2B pour voir les prix et les rabais.
The 3-phase bidirectional power meter EMU Professional II 3/5 TCP/IP LP for DIN rail mounting features a built-in LAN interface with Modbus TCP communication and web-server. The indirect power meter is designed for energy management as per ISO 50001 and energy cost billing.Logbook for events and configuration changes related to MID / PTB regulations and Built-in load profile memory with a memory depth of over 3 years at a 15-minute interval.
Features
Bidirectional three-phase power meter with LAN TCP/IP interface
Remote reading via Modbus TCP and API
Webserver access protection with password
Logbook for events and configuration changes related to weights and measures regulations
Logging of different measurement values and export to CSV or via API
Memory depth of over 3 years at a 15-minute interval
3x230/400V
1 or 5 A transformer connection for up to 20000/5 or 4000/1 A
MID B+D, for billing purposes
PTB-A 50.7 approval
Accuracy class B (1%)
TCP/IP interface
The built-in LAN TCP/IP interface is protected against dirt and manipulation.You can analyse different measurement readings via your web browser and IP address in a LAN or WAN.
Remote reading via Modbus TCP
HTTP-GET API
NTP time server
Buffered clock with synchronisation
DHCP or fixed IP
Modbus TCPModbus TCP is similar to Modbus RTU, but TCP/IP packages are used to transfer data. TCP-Port 502 is reserved for Modbus TCP.
Power meter readings
Active energy consumption (kWh) and supply (kWh)
Reactive energy consumption (kWh) and supply (kWh)
Active power (kw)
Reactive power (kvar)
Apparent power (kVA)
Current (A)
Frequency (Hz)
Number of voltage failures
LCD-Display
Reading and setting parameters is user-friendly by a 38x28 mm graphic LCD display with LED backlight. This provides excellent visibility of numbers and letters.Display language e.g. english or german can be selected by the keys.
Power meter configuration
Touch-sensitive control buttons are used for configuration. A sealable service button must be pressed for each configuration change.The current transformer ratio (1 or 5 A transformer, up for up to 20000/5 or 4000/1 A) can be configurable several times.Network parameters are easy to configure via the website or buttons.
S0 pulse output
The 3-phase power meter EMU Professional II 3/5 TCP/IP LP features a configurable S0 pulse output for active or reactive energy
Pulse rate per kWh / kvarH: 1,10,100, 1000 or 10000
Pulse length in milliseconds: 2ms, 10ms, 30ms, 40ms, 120 ms
Power meter configuration ex factory
Netwok configuration: DHCP
S0 pulse output: 10 Impulse/ 20 ms
Manufacturer
The 3-phase MID approved TCP/IP power meter meter is produced in Switzerland by EMU Electronic Ltd.More information: https://www.emuag.ch
Demandez un login B2B pour voir les prix et les rabais.
The 3-phase bidirectional power meter EMU Professional II 3/100 TCP/IP LP for DIN rail mounting features a built-in wired M-Bus interface and is suitable for energy management as per ISO 50001 and energy cost billing.Logbook for events and configuration changes related to MID / PTB regulations and Built-in load profile memory with a memory depth of over 3 years at a 15-minute interval.
Features
Bidirectional three-phase power meter with LAN TCP/IP interface
Remote reading via Modbus TCP and API
Webserver access protection with password
Logbook for events and configuration changes related to weights and measures regulations
Logging of different measurement values and export to CSV or via API
Memory depth of over 3 years at a 15-minute interval
3x230/400V
Direct connection up to 100 A
MID B+D, for billing purposes
PTB-A 50.7 approval
Accuracy class B (1%)
TCP/IP interface
The built-in LAN TCP/IP interface is protected against dirt and manipulation.You can analyse different measurement readings via your web browser and IP address in a LAN or WAN.
Remote reading via Modbus TCP
HTTP-GET API
NTP time server
Buffered clock with synchronisation
DHCP or fixed IP
Modbus TCPModbus TCP is similar to Modbus RTU, but TCP/IP packages are used to transfer data. TCP-Port 502 is reserved for Modbus TCP.
Power meter readings
Active energy consumption (kWh) and supply (kWh)
Reactive energy consumption (kvarh) and supply (kvarh)
Active power (kw)
Reactive power (kvar)
Apparent power (kVA)
Current (A)
Frequency (Hz)
Number of voltage failures
LCD-Display
Reading and setting parameters is user-friendly by a 38x28 mm graphic LCD display with LED backlight. This provides excellent visibility of numbers and letters.Display language e.g. english or german can be selected by the keys.
Power meter configuration
Touch-sensitive control buttons are used for configuration. A sealable service button must be pressed for each configuration change.Network parameters are easy to configure via the website or keys.
S0 pulse output
The 3-phase power meter EMU Professional II 3/100 TCP/IP LP features a configurable S0 pulse output for active or reactive energy
Pulse rate per kWh / kvarH: 1,10,100, 1000 or 10000
Pulse length in milliseconds: 2ms, 10ms, 30ms, 40ms, 120 ms
Power meter configuration ex factory
Netwok configuration: DHCP
S0 pulse output: 1'000 Impulse/ 40 ms
Manufacturer
The 3-phase M-Bus power meter meter is produced in Switzerland by EMU Electronic Ltd.More information: https://www.emuag.ch
Demandez un login B2B pour voir les prix et les rabais.
Functional cookies are absolutely necessary for the functionality of the web shop. These cookies assign a unique random ID to your browser so that your unhindered shopping experience can be guaranteed over several page views.
CSRF token:
The CSRF token cookie contributes to your security. It strengthens the security of forms against unwanted hacker attacks.
Cache handling:
The cookie is used to differentiate the cache for different scenarios and page users.
CAPTCHA integration
Information on origin:
The cookie stores the referrer and the first page visited by the user for further use.
PayPal payments
Timezone:
The cookie is used to provide the system with the user's current time zone.
Cookie settings:
The cookie is used to store the cookie settings of the site user over several browser sessions.
Session:
The session cookie stores your shopping data over several page views and is therefore essential for your personal shopping experience.
Activated cookies:
Saves which cookies have already been accepted by the user for the first time.
YouTube video
Wishlist
Cookies used for statistics and shop performance metrics.
Google Analytics
Tracking cookies help the shop operator to collect and evaluate information about the behaviour of users on their website.
Google Tagmanager
Google Analytics:
Google Analytics is used for traffic analysis of the website. Thereby statistics about website activities can be created and read out.
Livechat
Marketing cookies are used to display advertisements on the website in a targeted and individualized manner across multiple page views and browser sessions.
Google conversion tracking:
The Google Conversion Tracking Cookie is used to track conversions on the website effectively. This information is used by the site operator to target Google AdWords campaigns.
_gcl_aw:
Dieses Cookie wird gesetzt, wenn ein User über einen Klick auf eine Google Werbeanzeige auf die Website gelangt. Es enthält Informationen darüber, welche Werbeanzeige geklickt wurde, sodass erzielte Erfolge wie z.B. Bestellungen oder Kontaktanfragen der Anzeige zugewiesen werden können.
_gcl_au:
Enthält eine zufallsgenerierte User-ID.
Allows Google to collect personal data for online advertising and marketing.
Google Advertising
Allows Google to collect personal data for online advertising and marketing.
Google Advertising
Allows Google to collect personal data for online advertising and marketing.
Google Advertising
Crisp
Allows Google to collect personal data for online advertising and marketing.
Google Advertising
Allows Google to collect personal data for online advertising and marketing.
Google Advertising
Diese Website verwendet Cookies, um Ihnen die bestmögliche Funktionalität bieten zu können... Mehr Informationen.